1.
Environ Sci Ecotechnol ; 18: 100314, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37854462

RESUMO

A reduction in building occupancy can lead to stagnant water in plumbing, and the potential consequences for water quality have gained increasing attention. To investigate this, a study was conducted during the COVID-19 pandemic, focusing on water quality in four institutional buildings. Two of these buildings were old (>58 years) and large (>19,000 m2), while the other two were new (>13 years) and small (<11,000 m2). The study revealed significant decreases in water usage in the small buildings, whereas usage remained unchanged in the large buildings. Initial analysis found that residual chlorine was rarely detectable in cold/drinking water samples. Furthermore, the pH, dissolved oxygen, total organic carbon, and total cell count levels in the first draw of cold water samples were similar across all buildings. However, the ranges of heavy metal concentrations in large buildings were greater than observed in small buildings. Copper (Cu), lead (Pb), and manganese (Mn) sporadically exceeded drinking water limits at cold water fixtures, with maximum concentrations of 2.7 mg Cu L-1, 45.4 µg Pb L-1, 1.9 mg Mn L-1. Flushing the plumbing for 5 min resulted in detectable residual at fixtures in three buildings, but even after 125 min of flushing in largest and oldest building, no residual chlorine was detected at the fixture closest to the building's point of entry. During the pandemic, the building owner conducted fixture flushing, where one to a few fixtures were operated per visit in buildings with hundreds of fixtures and multiple floors. However, further research is needed to understand the fundamental processes that control faucet water quality from the service line to the faucet. In the absence of this knowledge, building owners should create and use as-built drawings to develop flushing plans and conduct periodic water testing.

2.
Environ Sci Technol ; 57(23): 8750-8759, 2023 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-37255211

RESUMO

Water quality impacts of new ion exchange point-of-entry residential softeners and their ability to be decontaminated following hydrocarbon exposure were investigated. During startup, significant amounts of total sulfur (445 ± 815 mg/L) and total organic carbon (937 ± 119 mg/L) were released into the drinking water that flowed through the softeners. Particulate organic carbon was released until the third regeneration cycle, and resin may also have been released. After one week of device use, softeners continued to cause organic carbon levels to be four to five times greater than background levels. Leached materials from the ion-exchange resin contributed to chlorine decay. When resins were exposed to hydrocarbon-contaminated water, they sorbed benzene, toluene, ethylbenzene, and xylenes (BTEX) and then desorbed the contaminants into drinking water during a 15 day flushing decontamination period. On day 15, benzene exceeded the federal drinking water limit for two of the four resins. The aged resin contributed to the greatest chlorine decay rates and sorbed and then retained the least amount of BTEX. Scale and biofilm on the aged resin likely prompted disinfectant reactivity and inhibited BTEX diffusion into the resin. Study results show that softeners exposed to hydrocarbon-contaminated water may need to be repeatedly flushed to remove BTEX contamination or be replaced. Additional work is recommended to better understand softener impacts on drinking water quality.


Assuntos
Água Potável , Poluentes Químicos da Água , Benzeno/análise , Cloro , Carbono , Derivados de Benzeno , Hidrocarbonetos , Tolueno/análise , Xilenos/análise , Poluentes Químicos da Água/análise
3.
Environ Sci Technol ; 57(16): 6360-6372, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-37036108

RESUMO

Residential buildings provide unique conditions for opportunistic premise plumbing pathogen (OPPP) exposure via aerosolized water droplets produced by showerheads, faucets, and tubs. The objective of this review was to critically evaluate the existing literature that assessed the impact of potentially enhancing conditions to OPPP occurrence associated with residential plumbing and to point out knowledge gaps. Comprehensive studies on the topic were found to be lacking. Major knowledge gaps identified include the assessment of OPPP growth in the residential plumbing, from building entry to fixtures, and evaluation of the extent of the impact of typical residential plumbing design (e.g., trunk and branch and manifold), components (e.g., valves and fixtures), water heater types and temperature setting of operation, and common pipe materials (copper, PEX, and PVC/CPVC). In addition, impacts of the current plumbing code requirements on OPPP responses have not been assessed by any study and a lack of guidelines for OPPP risk management in residences was identified. Finally, the research required to expand knowledge on OPPP amplification in residences was discussed.


Assuntos
Água Potável , Engenharia Sanitária , Abastecimento de Água , Habitação , Microbiologia da Água
4.
Water Res ; 211: 117997, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34999316

RESUMO

In recent years, drinking water-associated pathogens that can cause infections in immunocompromised or otherwise susceptible individuals (henceforth referred to as DWPI), sometimes referred to as opportunistic pathogens or opportunistic premise plumbing pathogens, have received considerable attention. DWPI research has largely been conducted by experts focusing on specific microorganisms or within silos of expertise. The resulting mitigation approaches optimized for a single microorganism may have unintended consequences and trade-offs for other DWPI or other interests (e.g., energy costs and conservation). For example, the ecological and epidemiological issues characteristic of Legionella pneumophila diverge from those relevant for Mycobacterium avium and other nontuberculous mycobacteria. Recent advances in understanding DWPI as part of a complex microbial ecosystem inhabiting drinking water systems continues to reveal additional challenges: namely, how can all microorganisms of concern be managed simultaneously? In order to protect public health, we must take a more holistic approach in all aspects of the field, including basic research, monitoring methods, risk-based mitigation techniques, and policy. A holistic approach will (i) target multiple microorganisms simultaneously, (ii) involve experts across several disciplines, and (iii) communicate results across disciplines and more broadly, proactively addressing source water-to-customer system management.


Assuntos
Água Potável , Legionella pneumophila , Comunicação , Ecossistema , Humanos , Engenharia Sanitária , Microbiologia da Água , Abastecimento de Água
5.
Microorganisms ; 8(9)2020 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-32971988

RESUMO

Premise plumbing conditions can contribute to low chlorine or chloramine disinfectant residuals and reactions that encourage opportunistic pathogen growth and create risk of Legionnaires' Disease outbreaks. This bench-scale study investigated the growth of Legionella spp. and Acanthamoeba in direct contact with premise plumbing materials-glass-only control, cross-linked polyethylene (PEX) pipe, magnesium anode rods, iron pipe, iron oxide, pH 10, or a combination of factors. Simulated glass water heaters (SGWHs) were colonized by Legionella pneumophila and exposed to a sequence of 0, 0.1, 0.25, and 0.5 mg/L chlorine or chloramine, at two levels of total organic carbon (TOC), over 8 weeks. Legionella pneumophila thrived in the presence of the magnesium anode by itself and or combination with other factors. In most cases, 0.5 mg/L Cl2 caused a significant rapid reduction of L. pneumophila, Legionella spp., or total bacteria (16S rRNA) gene copy numbers, but at higher TOC (>1.0 mg C/L), a chlorine residual of 0.5 mg/L Cl2 was not effective. Notably, Acanthamoeba was not significantly reduced by the 0.5 mg/L chlorine dose.

6.
AWWA Water Sci ; 2(4): e1186, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32838226

RESUMO

The unprecedented number of building closures related to the coronavirus disease (COVID-19) pandemic is concerning because water stagnation will occur in many buildings that do not have water management plans in place. Stagnant water can have chemical and microbiological contaminants that pose potential health risks to occupants. Health officials, building owners, utilities, and other entities are rapidly developing guidance to address this issue, but the scope, applicability, and details included in the guidance vary widely. To provide a primer of large building water system preventative and remedial strategies, peer-reviewed, government, industry, and nonprofit literature relevant to water stagnation and decontamination practices for plumbing was synthesized. Preventative practices to help avoid the need for recommissioning (e.g., routine flushing) and specific actions, challenges, and limitations associated with recommissioning were identified and characterized. Considerations for worker and occupant safety were also indicated. The intended audience of this work includes organizations developing guidance.

7.
Environ Sci Technol ; 54(18): 11453-11463, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32786341

RESUMO

When rainwater harvesting is utilized as an alternative water resource in buildings, a combination of municipal water and rainwater is typically required to meet water demands. Altering source water chemistry can disrupt pipe scale and biofilm and negatively impact water quality at the distribution level. Still, it is unknown if similar reactions occur within building plumbing following a transition in source water quality. The goal of this study was to investigate changes in water chemistry and microbiology at a green building following a transition between municipal water and rainwater. We monitored water chemistry (metals, alkalinity, and disinfectant byproducts) and microbiology (total cell counts, plate counts, and opportunistic pathogen gene markers) throughout two source water transitions. Several constituents including alkalinity and disinfectant byproducts served as indicators of municipal water remaining in the system since the rainwater source does not contain these constituents. In the treated rainwater, microbial proliferation and Legionella spp. gene copy numbers were often three logs higher than those in municipal water. Because of differences in source water chemistry, rainwater and municipal water uniquely interacted with building plumbing and generated distinctively different drinking water chemical and microbial quality profiles.


Assuntos
Água Potável , Legionella , Água Potável/análise , Chuva , Água , Microbiologia da Água , Qualidade da Água , Abastecimento de Água
8.
Front Microbiol ; 10: 2446, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31736893

RESUMO

Biofilm heterogeneity has been characterized on various scales for both natural and engineered ecosystems. This heterogeneity has been attributed to spatial differences in environmental factors. Understanding their impact on localized biofilm heterogeneity in building plumbing systems is important for both management and representative sampling strategies. We assessed heterogeneity within the confined engineered ecosystem of a shower hose by high-resolution sampling (200 individual biofilm sections per hose) on varying scales (µm to m). We postulated that a biofilm grown on a single material under uniform conditions should be homogeneous in its structure, bacterial numbers, and community composition. A biofilm grown for 12 months under controlled laboratory conditions, showed homogeneity on large-scale. However, some small-scale heterogeneity was clearly observed. For example, biofilm thickness of cm-sections varied up to 4-fold, total cell concentrations (TCC) 3-fold, and relative abundance of dominant taxa up to 5-fold. A biofilm grown under real (i.e., uncontrolled) use conditions developed considerably more heterogeneity in all variables which was attributed to more discontinuity in environmental conditions. Interestingly, biofilm communities from both hoses showed comparably low diversity, with <400 taxa each, and only three taxa accounting for 57%, respectively, 73% of the community. This low diversity was attributed to a strong selective pressure, originating in migrating carbon from the flexible hoses as major carbon source. High-resolution sampling strategy enabled detailed analysis of spatial heterogeneity within an individual drinking water biofilm. This study gives insight into biofilm structure and community composition on cm-to m-scale and is useful for decision-making on sampling strategies in biofilm research and monitoring.

9.
Artigo em Inglês | MEDLINE | ID: mdl-29619241

RESUMO

Bath toys pose an interesting link between flexible plastic materials, potable water, external microbial and nutrient contamination, and potentially vulnerable end-users. Here, we characterized biofilm communities inside 19 bath toys used under real conditions. In addition, some determinants for biofilm formation were assessed, using six identical bath toys under controlled conditions with either clean water prior to bathing or dirty water after bathing. All examined bath toys revealed notable biofilms on their inner surface, with average total bacterial numbers of 5.5 × 106 cells/cm2 (clean water controls), 9.5 × 106 cells/cm2 (real bath toys), and 7.3 × 107 cells/cm2 (dirty water controls). Bacterial community compositions were diverse, showing many rare taxa in real bath toys and rather distinct communities in control bath toys, with a noticeable difference between clean and dirty water control biofilms. Fungi were identified in 58% of all real bath toys and in all dirty water control toys. Based on the comparison of clean water and dirty water control bath toys, we argue that bath toy biofilms are influenced by (1) the organic carbon leaching from the flexible plastic material, (2) the chemical and biological tap water quality, (3) additional nutrients from care products and human body fluids in the bath water, as well as, (4) additional bacteria from dirt and/or the end-users' microbiome. The present study gives a detailed characterization of bath toy biofilms and a better understanding of determinants for biofilm formation and development in systems comprising plastic materials in contact with potable water.

10.
ISME J ; 12(5): 1344-1359, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29416124

RESUMO

Here we used flow cytometry (FCM) and filtration paired with amplicon sequencing to determine the abundance and composition of small low nucleic acid (LNA)-content bacteria in a variety of freshwater ecosystems. We found that FCM clusters associated with LNA-content bacteria were ubiquitous across several ecosystems, varying from 50 to 90% of aquatic bacteria. Using filter-size separation, we separated small LNA-content bacteria (passing 0.4 µm filter) from large bacteria (captured on 0.4 µm filter) and characterized communities with 16S amplicon sequencing. Small and large bacteria each represented different sub-communities within the ecosystems' community. Moreover, we were able to identify individual operational taxonomical units (OTUs) that appeared exclusively with small bacteria (434 OTUs) or exclusively with large bacteria (441 OTUs). Surprisingly, these exclusive OTUs clustered at the phylum level, with many OTUs appearing exclusively with small bacteria identified as candidate phyla (i.e. lacking cultured representatives) and symbionts. We propose that LNA-content bacteria observed with FCM encompass several previously characterized categories of bacteria (ultramicrobacteria, ultra-small bacteria, candidate phyla radiation) that share many traits including small size and metabolic dependencies on other microorganisms.


Assuntos
Bactérias/classificação , Água Doce/microbiologia , Bactérias/genética , Bactérias/isolamento & purificação , Análise por Conglomerados , Ecossistema , Ácidos Nucleicos/análise , Filogenia
11.
Water Res ; 131: 274-286, 2018 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-29304381

RESUMO

Shower hoses offer an excellent bacterial growth environment in close proximity to a critical end-user exposure route within building drinking water plumbing. However, the health risks associated with and processes underlying the development of biofilms in shower hoses are poorly studied. In a global survey, biofilms from 78 shower hoses from 11 countries were characterized in terms of cell concentration (4.1 × 104-5.8 × 108 cells/cm2), metal accumulation (including iron, lead, and copper), and microbiome composition (including presence of potential opportunistic pathogens). In countries using disinfectant, biofilms had on average lower cell concentrations and diversity. Metal accumulation (up to 5 µg-Fe/cm2, 75 ng-Pb/cm2, and 460 ng-Cu/cm2) seemed to be partially responsible for discoloration in biofilms, and likely originated from other pipes upstream in the building. While some genera that may contain potential opportunistic pathogens (Legionella, detected in 21/78 shower hoses) were positively correlated with biofilm cell concentration, others (Mycobacterium, Pseudomonas) had surprisingly non-existent or negative correlations with biofilm cell concentrations. In a controlled study, 15 identical shower hoses were installed for the same time period in the same country, and both stagnant and flowing water samples were collected. Ecological theory of dispersal and selection helped to explain microbiome composition and diversity of different sample types. Shower hose age was related to metal accumulation but not biofilm cell concentration, while frequency of use appeared to influence biofilm cell concentration. This study shows that shower hose biofilms are clearly a critical element of building drinking water plumbing, and a potential target for building drinking water plumbing monitoring.


Assuntos
Biofilmes , Microbiota , Engenharia Sanitária/instrumentação , Microbiologia da Água , Biofilmes/efeitos dos fármacos , Desinfetantes/farmacologia , Legionella/isolamento & purificação , Mycobacterium/isolamento & purificação , Inquéritos e Questionários
12.
Microbiome ; 5(1): 130, 2017 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-28978350

RESUMO

BACKGROUND: Several biotic and abiotic factors have been reported to influence the proliferation of microbes, including Legionella pneumophila, in hot water premise plumbing systems, but their combined effects have not been systematically evaluated. Here, we utilize simulated household water heaters to examine the effects of stepwise increases in temperature (32-53 °C), pipe material (copper vs. cross-linked polyethylene (PEX)), and influent assimilable organic carbon (0-700 µg/L) on opportunistic pathogen gene copy numbers and the microbiota composition, as determined by quantitative polymerase chain reaction and 16S rRNA gene amplicon sequencing. RESULTS: Temperature had an overarching influence on both the microbiota composition and L. pneumophila numbers. L. pneumophila peaked at 41 °C in the presence of PEX (1.58 × 105 gene copies/mL). At 53 °C, L. pneumophila was not detected. Several operational taxonomic units (OTUs) persisted across all conditions, accounting for 50% of the microbiota composition from 32 to 49 °C and 20% at 53 °C. Pipe material most strongly influenced microbiota composition at lower temperatures, driven by five to six OTUs enriched with each material. Copper pipes supported less L. pneumophila than PEX pipes (mean 2.5 log10 lower) at temperatures ≤ 41 °C, but showed no difference in total bacterial numbers. Differences between pipe materials diminished with elevated temperature, probably resulting from decreased release of copper ions. At temperatures ≤ 45 °C, influent assimilable organic carbon correlated well with total bacterial numbers, but not with L. pneumophila numbers. At 53 °C, PEX pipes leached organic carbon, reducing the importance of dosed organic carbon. L. pneumophila numbers correlated with a Legionella OTU and a Methylophilus OTU identified by amplicon sequencing. CONCLUSIONS: Temperature was the most effective factor for the control of L. pneumophila, while microbiota composition shifted with each stepwise temperature increase. While copper pipe may also help shape the microbiota composition and limit L. pneumophila proliferation, its benefits might be constrained at higher temperatures. Influent assimilable organic carbon affected total bacterial numbers, but had minimal influence on opportunistic pathogen gene numbers or microbiota composition. These findings provide guidance among multiple control measures for the growth of opportunistic pathogens in hot water plumbing and insight into the mediating role of microbial ecological factors.


Assuntos
Carbono , Temperatura Alta , Legionella pneumophila/crescimento & desenvolvimento , Microbiota/fisiologia , Microbiologia da Água , Cobre , Legionella pneumophila/genética , Legionella pneumophila/isolamento & purificação , Microbiota/genética , RNA Ribossômico 16S , Engenharia Sanitária , Abastecimento de Água
13.
ISME J ; 10(12): 2773-2775, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27137125

RESUMO

There is a growing interest in controlling-promoting or avoiding-the invasion of microbial communities by new community members. Resource availability and community structure have been reported as determinants of invasion success. However, most invasion studies do not adhere to a coherent and consistent terminology nor always include rigorous interpretations of the processes behind invasion. Therefore, we suggest that a consistent set of definitions and a rigorous conceptual framework are needed. We define invasion in a microbial community as the establishment of an alien microbial type in a resident community and argue how simple criteria to define aliens, residents, and alien establishment can be applied for a wide variety of communities. In addition, we suggest an adoption of the community ecology framework advanced by Vellend (2010) to clarify potential determinants of invasion. This framework identifies four fundamental processes that control community dynamics: dispersal, selection, drift and diversification. While selection has received ample attention in microbial community invasion research, the three other processes are often overlooked. Here, we elaborate on the relevance of all four processes and conclude that invasion experiments should be designed to elucidate the role of dispersal, drift and diversification, in order to obtain a complete picture of invasion as a community process.


Assuntos
Bactérias/classificação , Fenômenos Fisiológicos Bacterianos , Biodiversidade , Microbiota , Bactérias/genética , Bactérias/isolamento & purificação , Ecossistema , Modelos Biológicos
14.
Curr Opin Biotechnol ; 33: 87-94, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25578740

RESUMO

New microbial tools enable detailed quantification and characterization of complex drinking water (DW) microbiomes. Many opportunities exist from source to tap to apply this knowledge toward management of the microbiology. This requires consideration of the microbiome continuum across all phases harboring microbes (planktonic cells, biofilms, and cells attached to loose deposits) and across all stages (source, treatment, distribution, and premise). Biofilters can be optimized toward specific compound removal and can seed the distribution network (DN) with beneficial bacteria. Disinfection aggressively controls the microbiome, but may select for unwanted bacteria. Within premise plumbing, dramatic changes occur with unavoidable stagnation and pipe material influence. To supply safe DW sustainably, it is imperative that the field progress from characterization toward management of the DW microbiome.


Assuntos
Água Potável/microbiologia , Microbiologia da Água , Purificação da Água/métodos , Bactérias , Microbiota
15.
Environ Sci Technol ; 48(18): 10624-33, 2014 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-25118569

RESUMO

Temporary conversion to chlorine (i.e., "chlorine burn") is a common approach to controlling nitrification in chloraminated drinking water distribution systems, yet its effectiveness and mode(s) of action are not fully understood. This study characterized occurrence of nitrifying populations before, during and after a chlorine burn at 46 sites in a chloraminated distribution system with varying pipe materials and levels of observed nitrification. Quantitative polymerase chain reaction analysis of gene markers present in nitrifying populations indicated higher frequency of detection of ammonia oxidizing bacteria (AOB) (72% of samples) relative to ammonia oxidizing archaea (AOA) (28% of samples). Nitrospira nitrite oxidizing bacteria (NOB) were detected at 45% of samples, while presence of Nitrobacter NOB could not be confirmed at any of the samples. During the chlorine burn, the numbers of AOA, AOB, and Nitrospira greatly reduced (i.e., 0.8-2.4 log). However, rapid and continued regrowth of AOB and Nitrospira were observed along with nitrite production in the bulk water within four months after the chlorine burn, and nitrification outbreaks appeared to worsen 6-12 months later, even after adopting a twice annual burn program. Although high throughput sequencing of 16S rRNA genes revealed a distinct community shift and higher diversity index during the chlorine burn, it steadily returned towards a condition more similar to pre-burn than burn stage. Significant factors associated with nitrifier and microbial community composition included water age and sampling location type, but not pipe material. Overall, these results indicate that there is limited long-term effect of chlorine burns on nitrifying populations and the broader microbial community.


Assuntos
Cloraminas/química , Cloro/química , Água Potável/microbiologia , Microbiologia da Água/normas , Abastecimento de Água , Amônia/análise , Archaea/genética , Betaproteobacteria/genética , Cloraminas/análise , Cloro/análise , Água Potável/normas , Nitrificação , Nitritos/análise , Nitrobacter/genética , Oxirredução , RNA Ribossômico 16S/genética , Abastecimento de Água/normas